Hyperterminal programming
- #HYPERTERMINAL PROGRAMMING SERIAL#
- #HYPERTERMINAL PROGRAMMING DRIVER#
- #HYPERTERMINAL PROGRAMMING SOFTWARE#
If the connection was successful, a message about an unrecognized command may pop up. If the connection failed, the terminal window will return to the command prompt. Upon executing the screen command, the terminal window will go blank.For example, in the case of the pump in Step 3, which is connected by a USB-only cable, type the following into the Terminal window:Įxample screen /dev/tty.usbserial-A600AQM6 38400 To connect to the pump, use the screen command with the path associated with the connected pump and the baud rate.Check for connected USB devices using the following command: ls /dev/tty.usb*įor example, this command could return the following:.Ensure that the pump is plugged into the USB port of the computer using either the USB-only cable (Fusion/OEM only) or the USB-to-DB9 adapter (any pump).These instructions assume that the pump is connected to a USB port of the computer. Procedure for Connecting the Syringe Pump Using screen in macOS and Linuxīoth macOS and Linux have the capability of connecting using the built-in Terminal application and the screen command. Typically, if the baud rate is not set correctly, there will be garbled or no response to any commands. This means that Nexus and Nanojet systems should always have this value set to 9600. However, if a DB9-only or USB-to-DB9 connection is used, the baud rate must be set to 9600. Generally, the pump should be set to use the higher baud rate (38400) if a USB-only connection is used.
#HYPERTERMINAL PROGRAMMING SERIAL#
* The baud rate setting for the serial connection must match the baud rate set in the pump settings GUI for the Fusion and OEM systems. Regardless of the operating system being used, the program controlling the serial connection should use the following settings procedure to connect to the syringe pump: Setting
#HYPERTERMINAL PROGRAMMING DRIVER#
We developed a LabVIEW™ Driver for Chemyx Fusion Syringe Pumps, a freeware that helps you interact with Fusion Series Syringe Pumps (Both VI Package Manager and Source code are available).įor the Fusion 100 and Fusion 200, the TTL Connection is the footswitch port.
#HYPERTERMINAL PROGRAMMING SOFTWARE#
In addition to these terminal programs, the LabVIEW and MATLAB software packages provide serial connection capabilities that allow users to programmatically control the pumps.
![hyperterminal programming hyperterminal programming](https://helpdeskgeek.com/wp-content/pictures/2009/12/teraterm.png)
Here is a list of some third-party programs that can be used in the syringe pump connection procedure: Application Because HyperTerminal was removed in the more recent versions of Windows, a third-party program ( e.g., TeraTerm) will be necessary to connect with computers running Windows Vista and later. There are also numerous third-party programs for serial connections that exist for each operating system that may provide easier use and more features. On macOS and Linux the screen command in the built-in Terminal app can be used to control the pump. On Windows XP and earlier operating systems, HyperTerminal can be used to control the syringe pump procedure.
![hyperterminal programming hyperterminal programming](https://www.file-extension.info/images/resource/screenshots/thmb/hyperterminal.png)
Most computer operating systems ( e.g., Windows, macOS, Linux, etc.) have built-in terminal programs that can be used to send the commands that run the pump.